Rev. 1.00 12-02-13 13/41
11936 Broken T.38 transmission
The problem manifests itself through continuous „voice‟ detection at the beginning of the FAX
transmission. It appeared if the SmartNode was located on the calling side of the call (A-Side)
and affected all BRI, FXS, and FXO devices except SN4660/SN4670. All issues have been
fixed and T.38 FAX transmission is working again for the above listed device series.
11942 Redirection service for provisioning supported in factory configuration
The product families of SN4660/SN4670 and SN4970/SN4980/SN4990 now support the Patton
redirection service for provisioning of customer specific configuration when booting up with the
factory configuration.
11950 Modified memory layout for SDTA, SN4552, SN4554 and SN5200
During the boot process the memory is a limited resource. Therefore the memory layout of the
products SDTA, SN4552, SN4554 and SN5200 has been slightly adapted to make better use of
the memory.
11954 FXS hanging calls
If an „interface fxs‟ in „context cs‟ was configured for „signal disconnect‟ by loop-break, the call
has never been completely terminated. Consequently, on an interface configured for loop-break
it was not possible anymore to setup further calls after dropping the first connection.
11957 Basic PRACK scenario broken
SmartWare behaves incorrectly in the following PRACK scenario. SmartWare receives an
incoming INVITE request on a SIP interface. This request states that the remote device
supports PRACK. It also contains a body with SDP description. SmartWare sends a provisional
response with an SDP description too. In this response the acknowledgement with PRACK is
requested. When the remote device now sends the PRACK request to acknowledge the
provisional response, and this PRACK request does not contain a SDP description, SmartWare
terminates the call with a “488 Not Acceptable Here”. This misbehavior is now fixed and the call
is continued after receiving the PRACK request.
11965 Spurious error messages from G.S interface
If a PPPoE PVC is created with a serial connection then an error message appears. This error
message in not harmful because all commands are successfully executed. The reason is that a
feature is turned off which it already is by default. This spurious error message has now been
removed.
11968 Missing command „payload-rate‟ on SN4660/SN4670
The command „payload-rate‟ in the „port dsl‟ mode was missing on SN4660/SN4670 devices
when using tab completion. It was successfully executed when typed manually though. The
command is now fully supported also on SN4660/SN4670.
11983 Verbose software upgrade of G.S interface card
Commenti su questo manuale