Rev. 1.00 12-02-13 22/41
CTS11786
On older SmartNodes the two debug monitors debug media-gateway rtp and debug call-control print out
incorrect RTCP jitter values.
CTS11816
The command „call-control call drop <call>‟ is not behaving as expected. It drops all calls but does not
completely teardown all internal structures. Consequently the call numbers of the dropped call cannot
be used anymore for further calls after executing this command. The same is true for the “Drop all”
button on the web interface on the “Active Calls” tab of the Call-Router section.
CTS12027
The following configuration may create duplicate packets: If one physical ethernet port is bound to two
IP interfaces with different IP addresses and on both IP interfaces a SIP gateway is bound and some
static routes are configured, then the SIP gateways may receive duplicate UDP packets.