Caveat - Known Limitations
The following list refers to open cases in the Change Tracking System 'CTS'
CTS2236
Only G.723 high rate (6.3kbps) supported by H.323 (receive and transmit).
CTS2702
TFTP may not work with certain TFTP servers, namely the ones that change the port number in the reply.
When using the SolarWinds TFTP server on the CD-ROM this problem will not occur.
CTS2980
With 10bT Ethernet ports, only the half duplex mode works. (With 10/100bT Ethernet ports, all
combinations work.)
CTS3233
The SolarWinds TFTP server version 2.2.0 (1999) does not correctly handle file sizes of n * 512 Bytes.
Use version 3.0.9 (2000) or higher.
CTS3760
The SIP penalty-box feature does not work with TCP. When the penalty box feature is enabled, the TCP
transport protocol must be disabled using the „no transport tcp‟ command in the SIP gateway
configuration mode.
CTS3924
Changing a call-progress tone has no effect. Adding a new call-progress tone and using it from the tone
set profile works however.
CTS4031
The Caller-ID message length on FXS hardware with Chip Revision numbers below V1.5 is restricted to
32 bytes. If the message is longer the message will be truncated. The FXS Chip Revision can be
displayed using the „show port fxs detail 5‟ CLI command.
CTS4038
When doing 'shutdown' and then 'no shutdown' on an ethernet port that is bound to an IP interface that
receives its IP address over DHCP, the IP interface does not renew the lease.
CTS4077
Using the command „terminal monitor-filter‟ with regular expressions on systems under heavy load can
cause a reboot.
CTS4335
The duration of an on-hook pulse declared as flash-hook has been raised from 20ms to 1000ms, to
cover the most country specific flash hook durations. Existing installations should not be affected, as all
on-hook pulses lower than 1000ms are declared as flash-hook, including the previous default of 20ms.